Home / Products / Downloads

VentMaster 5.7.5 build 5

(Download) 

Modular air handling units' 3D modeling and selection software.

History

2017-03-03 Version 5.7.2 Changes: 1. Possibility to select gas-fired heater with natural gas or propane gas burner. Indoor or outdoor versions. Nominal capacity from 11 to 600kW. Nominal airflow from 1500 to 50000 m3/h. Heating efficiency up to 91% 2. Possibility to select pressure gauge for direct driven fan. Pressure gauge located on the doors outside the fan section and shows airflow in m3/s and m3/h 3. Possibility to select printout language before print preview and printing. No need to change interface language if you need printout in other language 2017-02-24 Version 5.7.1 Changes: 1. Filter dimensions changed for AmberAir SW50. Now all filters have Eurovent dimensions (592x592, etc.) 2. Possibility to choose spare filters sets for all kind of filters 2017-02-03 Version 5.7.0 Changes: 1. SmartAir brand changed to AmberAir 2. Possibility to choose pressure taps for heat recovery and coils sections 3. Possibility to choose both internal and external connections between sections 4. Possibility to add outdoor grills or hood on corner section 5. Modular power socket selection feature added 2016-12-23 Version 5.6.1 Changes: 1. Terminated the selection and production of the uniAir range AHU's 2. Zhiell-Abegg fans dll have been updated 3. Optimized calculation of steam humidifiers 4. Optimized section lengths for water and DX coolers 5. Price updates for units with control system
down
Line below arrow

VentMaster V5 Revit 2016 Plug-In 1.00

(Download) 

VentMaster V5 Revit 2016 Plug-In.

History

2016/11/11 Version 1.00: -
down
Line below arrow

VentMaster V5 Revit 2017 Plug-In

(Download) 

Line below arrow

VentMaster V5 Revit Plug-In installation guide

(Download) 

Line below arrow

MB Gateway FIRMWARE 1.08

(Download) 

Network module.

History

2017-02-21 Version 1.08 1. Features: 1.1 Transceiver baudrate setting 1.2 Auto open "index.htm" files 1.3 Date/time synchronization with server 1.4 Service mode activation by pressing the button 2016 09 19 Version 1.07 1. Added datalogger feature 2. Transceiver function bugs fixed 3. FTP, HTTP bugs fixed 2016-07-01 Version 1.06 1. Added DHCP support
down
Line below arrow

MB Gateway web application 1.08.2

(Download) 

History

2017-04-26 Version 1.08.2 Small bug fixes 2017-04-12 Version 1.08.1 Bug fixes 1. Modbus slave device recognition issue; 2017-02-21 Version 1.08.0 USER WEB: 1. Features 1.1 New alarms, their translations (LT,EN); 1.2 Enable/Disable hostname removed, hostname is now always enabled; 1.3 New advanced option in mb-gateway configuration window; 1.4 New menu with paging; 1.5 New humidity control page; 1.6 Dryness protection moved from “other“ to humidity; 1.7 Winter/Summer humidity control, boost control in humidity page; 1.8 New CO2 level page, select CO2 level option (only shown on specific settings); 1.9 Multicontrol – save all function; 1.10 Multicontrol – air handling unit count limited to 32, addresses 1-247; 1.11 Connection lost message of air handling unit is not found; 1.12 Percentage control, only active if fixed speeds option is set to “no”; 1.13 If percentage control is > 20, option to control temperature is shown. 1.14 MCB 1.10 support 2. Bug fixes 2.1 DHCP enabled/IP change sequence changed; 2.2 Bug where you couldn’t change password; 2.3 Other bugfixes (dhcp, multicontrol, tooltips, icons); ADVANCED WEB 1. Features 1.1 Multilanguage 1.2 Graphs: - Real time graphs - Time inverval graphs - 30 min interval graph 1.3 Logger variables: - Add/edit/delete variables 1.4 Logger group: - Add/edit/delete group 1.5 Transceiver: - Add/edit/delete transceiver variable - Add/edit/delete transceiver node 1.6 Support Bacnet/IP protocol configuration 1.7 MB-GATEWAY general configuration 1.8 Time synchronization MCB SERVICE/ADJUSTER WEB - MCB 1.10 support 2016-07-01 Version 1.06 1. Added DHCP support 2. Other bug fixes Version 1.05 - Version 1.04 1. Added a feature, so when CO2 or RH sensor values are lower than 1%, they aren’t shown in the main/status pages. 2. Fixed a bug where it would be possible to set the date in an incorrect format, for example, the date 31/02/2016 is for a month that only has 29 days; after the fix, the save button gets disabled, before the fix, the next month would be recalculated and the result would be 02/03/2016. 3. Added an SAF_flow and EAF_flow display near the status window in PRV. Version 1.03 1. Added multi-unit support. 2. Changed the design of the MB-gateway setup. 3. Multi-unit selection added to the main ventilation-control page and MB-gateway setup. 4. Multi-unit settings added to the MB-gateway setup. 5. MB-gateway configuration separated from the MB-gateway setup on a different page. 6. Added loading text message when selecting a new Unit in the ventilation control. Version 1.02 1. Fixed a bug, where some critical alarms weren’t shown. 2. Added SE, FI, DE translations for the MB-gateway. 3. Fixed a bug, where clicking reset in the alarm window wouldn‘t display the loading screen properly.
down
Line below arrow

P-touch firmware 1.01.3

(Download) 

Remote control panel.

History

2016-06-23 Version 1.01.3 1. Addedd MCB Full recirculation in MENU > Setpoints Version 1.01.2 - Version 1.01.1 1. MCB Date and Time, fixed bug for not setting time MCB Show Pa and m3/h for the adjuster when changing airflow values, if the fan’s control type is Pressure or Airflow PRV; 2. Fixed wrong values for the Heatexchanger and Heater types.
down
Line below arrow

P-touch update manual

(Download) 

Line below arrow

MCB tool 1.00

(Download) 

MCB Tool software imports MCB control board settings from MCB to PC and exports MCB control board settings from PC to MCB.

Line below arrow

MCB tool manual

(Download) 

Line below arrow
SALDA UAB
Ragainės g.100, Šiauliai LT-78109 LITHUANIA
Tel. +370 41 540 415 Fax. +370 41 540 417
office@salda.lt www.salda.lt